It is shown how recorder described made it possible to take vibration data from passenger passenger compartment of NC-135 jet aircraft with only few hours' notice prior to flight departure; eclipse monitoring camera mount was instrumented for vibration and combined flight and operation inputs indicated that hydraulic pumps would have to be relocated to keep vibration levels low; flight data measured on aircraft structural members are presented with samples of composite oscillographs along with complete bandpass peak distribution plots for several mission flight conditions.


    Access

    Access via TIB

    Check availability in my library


    Export, share and cite



    Title :

    Impromptu vibration data acquisition with ELI-31 recorder


    Additional title:

    Proc Inst Environ Sci


    Contributors:

    Conference:

    13th Annual Technical Meeting -- Institute of Environmental Sciences ; 1967 Vibrations



    Publication date :

    1967


    Size :

    11 pages


    Type of media :

    Conference paper


    Type of material :

    Print


    Language :

    English


    Keywords :



    An UAV Mounted Intelligent Monitoring System for Impromptu Air Quality Assessments

    Carrozzo, M. / De Vito, S. / Esposito, E. et al. | British Library Conference Proceedings | 2019




    Data recorder

    Online Contents | 1994