The insertion of the communication network in the feedback control loop makes some problems about the QoS. One important issue is the network-induced delay that occurs while exchanging data among devices connected to the shared medium. The purpose of this paper is to design an improved internal model controller to control a plant with time delays. Compared with ordinary internal model controllers, there is an additional feedback loop in the new architecture. The simulation results demonstrate that the control system has satisfied robustness performance.
An improved internal model control algorithm for NCS with networked-delay
2004-01-01
263075 byte
Conference paper
Electronic Resource
English
Generalized Predictive Control Algorithm with Dynamic Delay in Networked Control System
British Library Online Contents | 2008
|Model Predictive Control of Networked Control Systems with Time-Delay
British Library Online Contents | 2008
|Predictive Input Delay Compensation with Grey Predictor for Networked Control System
BASE | 2015
|