This paper proposed a novel approach to calculate the iron loss under DC bias condition using modified Jiles-Atherton (JA) model. The influence of DC bias on the JA model is analyzed. The parameters in the JA model are extracted from BH loops without DC bias but they are applicable for the one under DC bias condition. Thus the modified JA model is practically convenient for iron loss prediction. Moreover, the parameter identification is fast. In addition, the influence of different magnetic induction levels and frequency is incorporated in the model. An accurate measurement system is established to measure the BH loops and iron loss. The tested results are demonstrated and compared with the predicted iron loss to verify the modified JA model.


    Access

    Check access

    Check availability in my library

    Order at Subito €


    Export, share and cite



    Title :

    A modified jiles-atherton model for estimating the iron loss of electrical steel considering DC bias


    Contributors:
    Li, Zhaokai (author) / Huang, Xiaoyan (author) / Wu, Lijian (author) / Chen, Jituo (author) / Zhong, Yunlong (author) / Ma, Jien (author) / Fang, Youtong (author)


    Publication date :

    2018-04-01


    Size :

    693891 byte




    Type of media :

    Conference paper


    Type of material :

    Electronic Resource


    Language :

    English



    Minor loop dynamic Jiles-Atherton model in giant magnetostrictive actuator

    Gao, Xiaohui / Liu, Yongguang / Pei, Zhongcai | British Library Online Contents | 2016




    Estimating Bias Error Distributions

    Liu, T. / Finley, T. D. / AIAA | British Library Conference Proceedings | 2001


    Estimating bias error distributions

    Liu, Tianshu / Finley, Tom | AIAA | 2001