Results of 23 borings made in Section K006 of Vienna Route of the Washington Metropolitan Area Metro System at the location of West Falls Church Station and its parking lot and ancillary structures are described. The investigation was made to determine subsurface conditions in connection with design and construction of the station complex. The report contains several geological sections through the various borings, logs of the borings, results of laboratory testing of the subsoils, conclusions regarding subsoil properties and a summary of anticipated design and construction problems.