A summary of the conceptual design of the Skylab sleep monitoring experiment and a comprehensive compilation of the data-analysis results from the three Skylab missions is presented. One astronaut was studied per flight, electroencephalographic, electro-oculographic, and headmotion signals acquired during sleep by use of an elastic recording cap containing sponge electrodes and an attached miniature preamplifier/accelerometer unit are shown. A control-panel assembly, mounted in the sleep compartment, tested electrodes, preserved analog signals, and automatically analyzed data in real time (providing a telemetered indication of sleep stage). Results indicate that men are able to obtain adequate sleep in regularly scheduled eight-hour rest periods during extended space missions.