An experimental and theoretical investigation of fuselage incidence effects on two fighter aircraft models, which differed in wing planform only, has been conducted in the Langley Unitary Plan Wind Tunnel at Mach numbers of 1.6, 1.8, and 2.0. Results were obtained on the two models at fuselage incidence angles of 0 deg, 2 deg, and 5 deg. The fuselage geometry included two side-mounted, flow-through, half-axisymmetric inlets and twin vertical tails. The two planforms tested were cranked wings with 70 deg/66 deg and 70 deg/30 deg leading-edge sweep angles. Experimental data showed that fuselage incidence resulted in positive increments in configuration lift and pitching moment; most of the lift increment can be attributed to the fuselage-induced upwash acting on the wing and most of the pitching-moment increment is due to the fuselage. Theoretical analysis indicates that linear-theory methods can adequately predict the overall configuration forces and moments resulting from fuselage upwash, but a higher order surface-panel method (PAN AIR) more accurately predicted the distribution of forces and resulting moments between the components.