The purpose of the Temperature-Controlled Quartz Crystal Microbalance (TQCM) system on STS-2 was to measure condensible molecular flux in the payload bay of the Space Shuttle as a function of temperature, direction, and time. Five quartz crystal microbalance sensors were located in the IECM to measure molecular adsorption in each of the Orbiter axes, +X (fore), -X (aft), +Y (starboard), -Y (port), and -Z (up, perpendicular to payload bay). The temperature of each sensor was controlled by a thermoelectric device so contamination could be measured as a function of four preset temperatures: +30, 0, -30, and -60 C. When orbital altitude was reached, the TQCM sensors began their orbital measuring cycle routine. The sensors were commanded to 80 C for 30 min, which was used as an initial clean-up. They were then stepped through a program of 2-nr collection periods at each temperature with a 30-min, 80 C period between each collection period. The collection periods progressed in descending order from +30 to -60 C and, then the cycle was repeated. Since the STS-2 orbital phase lasted approximately 53 hrs, the TQCM system completed four cycles and was in the fifth when the mission was terminated.
Temperature-controlled quartz crystal microbalance measurements on Space Transport System (STS-2)
1983-01-01
Conference paper
No indication
English
ATS-6 Quartz-Crystal Microbalance
IEEE | 1975
|ATS-6 - Quartz-Crystal Microbalance
NTRS | 1975
|British Library Conference Proceedings | 1994
|