Water leakage in heat exchanger measured directly with help of electroytic hygrometer. In new technique, flow of nitrogen gas set up in one loop of heat exchanger. Other loop filled with water under pressure. Water concentration produced by leakage of water into nitrogen flow measured by hygrometer. New measurement method determines water concentrations up to 2,000 parts per million with accuracy of +/- 5 percent.


    Access

    Access via TIB

    Check availability in my library


    Export, share and cite



    Title :

    Measuring Heat-Exchanger Water Leakage


    Contributors:

    Published in:

    Publication date :

    1986-06-01



    Type of media :

    Miscellaneous


    Type of material :

    No indication


    Language :

    English


    Keywords :


    Heat exchanger corrosion, corrosion protection and leakage repair