The postflight performance evaluation of the X-ray telescope was summarized. All payload systems and subsystems performed well within acceptable limits, with the sole exception of the light-blocking prefilters. Launch, flight and recovery were performed in a fully satisfactory manner. The payload was recovered in a timely manner and in excellent condition. The prefilter performance analysis showed that no X-ray images were detected on the processed flight film. Recommendations for improved performance are listed.
A normal incidence X-ray telescope
1987-01-01
Report
No indication
English
Normal Incidence X-Ray Telescope Sounding Rocket Payload
NTIS | 1987
|Development of a 1m-normal-incidence-EUV-telescope