The elements of Brayton technology development emphasize power conversion system risk mitigation. Risk mitigation is achieved by demonstrating system integration feasibility, subsystem/component life capability (particularly in the context of material creep) and overall spacecraft mass reduction. Closed-Brayton-cycle (CBC) power conversion technology is viewed as relatively mature. At the 2-kWe power level, a CBC conversion system Technology Readiness Level (TRL) of six (6) was achieved during the Solar Dynamic Ground Test Demonstration (SD-GTD) in 1998. A TRL 5 was demonstrated for 10 kWe-class CBC components during the development of the Brayton Rotating Unit (BRU) from 1968 to 1976. Components currently in terrestrial (open cycle) Brayton machines represent TRL 4 for similar uses in 100 kWe-class CBC space systems. Because of the baseline component and subsystem technology maturity, much of the Brayton technology task is focused on issues related to systems integration. A brief description of ongoing technology activities is given.
Research and Technology Activities Supporting Closed-Brayton-Cycle Power Conversion System Development
2nd International Energy Conversion Engineering Conference ; 2004 ; Providence, RI, United States
2004-01-01
Preprint
No indication
English
Technology Concept for a Near-Term Closed Brayton Cycle Power Conversion Unit
British Library Conference Proceedings | 2003
|Predicting the behavior of solar dynamic closed Brayton cycle power conversion systems
Tema Archive | 1988
|