A short description of an industrial size chemical heat pump prototype (CaCl2-NH3) is given. The test results are presented by the graphs of the temporal evolution of the prototype parameters. The results of the actual state of experimentation show that cold production in the range of -30°/-20°C temperatures may be interesting for practical applications. Test results are also given for the heat production mode.