Experimental investigations have been carried out to determine the AC system performance with HFO-1234yf as the working fluid. System level bench tests have been conducted with an AC system from a 2008 MY mid-sized sedan. The cabin interior condition is held constant at 20°C and 50% RH and evaporator airflow rate is varied from 5 to 9 m₃/min (83 to 150 lps). The dry bulb temperature for the engine compartment is varied from 25 to 45°C. The compressor speed is varied from 800 to 3000 rpm and the air velocity over the condenser is varied from 2 to 10 m/s (546 to 2730 lps). Detailed test results have been presented in the paper.
Experimental Investigation of AC System Performance with HFO-1234yf as the Working Fluid
Sae Technical Papers
SAE 2010 World Congress & Exhibition ; 2010
2010-04-12
Conference paper
English
SAE Technical Papers | 2011
|British Library Conference Proceedings | 2011
|Experimental Performance of a Parallel Flow Condenser with HFO-1234yf as the Working Fluid
SAE Technical Papers | 2010
|R-1234yf [HFO-1234yf] Refrigerant Electronic Leak Detectors, Minimum Performance Criteria
SAE Technical Papers | 2016
R-1234yf [HFO-1234yf] Refrigerant Electronic Leak Detectors, Minimum Performance Criteria
SAE Technical Papers | 2011