Abstract To investigate the mechanical responses of secondary lining of high-speed railway tunnel, two numerical models for simulating Reinforced Concrete Secondary Lining (RCSL) and Plain Concrete Secondary Lining (PCSL) are built respectively based on the principle of soil-structure interaction. The simulations are performed under different values of coefficient of lateral pressure (λ). The numerical results indicate that the embedded reinforcement enhances the strength of secondary lining. The coefficient of lateral pressure has significant influence on the secondary lining strength.
Mechanical Analysis of Secondary Lining of High-Speed Railway Tunnel
KSCE Journal of Civil Engineering ; 22 , 7 ; 2384-2389
2017-09-15
6 pages
Article (Journal)
Electronic Resource
English
Mechanical Analysis of Secondary Lining of High-Speed Railway Tunnel
Online Contents | 2018
|Tunnel lining on the Virginian railway
Engineering Index Backfile | 1913
Three Dimensional Numerical Simulation Study on Lining Pressure of High-Speed Railway Tunnel
Trans Tech Publications | 2011
|Mechanized lining repairing method for operating railway tunnel
European Patent Office | 2024
|Concrete lining of connaught tunnel, Canadian Pacific railway
Engineering Index Backfile | 1921