Abstract Three-level inverters are increasingly used in high-voltage and high-power applications. The fault diagnosis problem of the IGBTs gets highly attention considering to the safety and reliability of the system. Therefore, the IGBT open-circuit fault diagnosis of the three-level neutral point clamped (NPC) inverter is discussed in this paper. The output voltage of the inverter is analyzed when open-circuit fault occurs under open-loop condition. An improved algorithm is proposed based on the former results, which can be applied in the fault diagnosis of the open-circuit IGBTs in the closed-loop control system. The experimental results show that the proposed method can locate the fault IGBTs accurately and quickly with one open-circuit IGBTs.
IGBT Open-Circuit Fault Diagnosis for Closed-Loop System of Three-Level NPC Inverters
1st ed. 2016
2016-01-01
9 pages
Article/Chapter (Book)