A Passive thermal management scheme is devised while taking various Opto-thermal, Opto-mechanical & space environmental constraints into consideration. The finite element model of the thermal management scheme is established in NX NASTRAN to analyze the design w.r.to the given payload and satellite design parameters. The scheme is based on flexible thermal straps made of copper material. This scheme will help in achieving the desired thermal management while isolating the IDDCA assembly from the external vibrations and loads. The scheme is validated through implementation on the actual IDDCA & measuring the change in temperature w.r.to time at critical locations.


    Access

    Check access

    Check availability in my library

    Order at Subito €


    Export, share and cite



    Title :

    Thermal Management Scheme for SWIR IDDCA Used in Space Payloads


    Additional title:

    Lect. Notes Electrical Eng.




    Publication date :

    2023-01-03


    Size :

    7 pages





    Type of media :

    Article/Chapter (Book)


    Type of material :

    Electronic Resource


    Language :

    English