A segmented involute-foil regenerator has been designed, microfabricated and tested in an oscillating-flow rig with excellent results. During the Phase I effort, several approximations of parallel-plate regenerator geometry were chosen as potential candidates for a new microfabrication concept. During Phase II, re-planning of the effort led to test plans based on nickel disks, microfabricated via the LiGA process, only. A stack of nickel segmented-involute-foil disks was tested in an oscillating-flow test rig. These test results yielded a performance figure of merit (roughly the ratio of heat transfer to pressure drop) of about twice that of the 90 percent random fiber currently used in small ~100 W Stirling space-power convertors-in the Reynolds Number range of interest (50 to 100). A Phase III effort is now underway to fabricate and test a segmented-involute-foil regenerator in a Stirling convertor. Previous Sage Stirling model projections have indicated that a segmented-involute-foil regenerator is capable of improving the performance of an optimized involute-foil engine by 6 to 9 percent; it is also anticipated that such involute-foil geometries will be more reliable and easier to manufacture with tight-tolerance characteristics, than random-fiber or wire-screen regenerators. Beyond the near-term Phase III regenerator fabrication and engine testing, other goals are (1) fabrication from a material suitable for high temperature Stirling operation (up to 850 Degree C for current engines; up to 1200 Degree C for a potential engine-cooler for a Venus mission), and (2) reduction of the cost of the fabrication process to make it more suitable for terrestrial applications of segmented involute foils. Past attempts have been made to use wrapped foils to approximate the large theoretical figures of merit projected for parallel plates. Such metal wrapped foils have never proved very successful, apparently due to the difficulties of fabricating wrapped-foils with uniform gaps and maintaining the gaps under the stress of time-varying temperature gradients during start-up and shut-down, and relatively-steady temperature gradients during normal operation. In contrast, stacks of involute-foil disks, with each disk consisting of multiple involute-foil segments held between concentric circular ribs, have relatively robust structures. The oscillating-flow rig tests of the segmented-involute-foil regenerator have demonstrated a shift in regenerator performance strongly in the direction of the theoretical performance of ideal parallel-plate regenerators.


    Access

    Access via TIB

    Check availability in my library

    Order at Subito €


    Export, share and cite



    Title :

    A microfabricated involute-foil regenerator for stirling engines


    Additional title:

    Ein mikrogefertigter Evolventen-Foliengenerator für Stirlingmotoren


    Contributors:
    Tew, Roy (author) / Ibrahim, Mounir (author) / Danila, Daniel (author) / Simon, Terrence (author) / Mantell, Susan (author) / Sun, Liyong (author) / Gedeon, David (author) / Kelly, Kevin (author) / McLean, Jeffrey (author) / Wood, Gary (author)


    Publication date :

    2007


    Size :

    25 Seiten, 34 Bilder, 6 Tabellen, 15 Quellen



    Type of media :

    Conference paper


    Type of material :

    Print


    Language :

    English




    A Microfabricated Involute-Foil Regenerator for Stirling Engines

    Tew, Roy / Ibrahim, Mounir / Danila, Daniel et al. | AIAA | 2007


    Computational Modeling of a Segmented-Involute-Foil Regenerator for Stirling Engines

    Ibrahim, Mounir B. / Danila, Daniel / Simon, Terrence W. et al. | AIAA | 2009


    Jet Penetration Into a Scaled Microfabricated Stirling Cycle Regenerator

    Sun, Liyong / Simon, Terrence / Mantell, Susan et al. | AIAA | 2008