A survey of the general problem of aerothermal reentry is made, showing the complexity of the problem for HERMES as well as for future ASTS. The present status of the TPS solution choosen for HERMES is given. Under consideration are ceramic composites or carbon carbon for hot structures, insulation using for hot zones either ceramic composite shingles plus internal multiscreen insulation or ceramic tiles, and for lower temperature zones flexible external insulation. The difference between HERMES and other potential Space Transportation Systems are studied. A comparison is made between HERMES solutions and other possible TPS systems.


    Access

    Access via TIB

    Check availability in my library


    Export, share and cite



    Title :

    Passive thermal protection systems for HERMES


    Additional title:

    Passive Waermeschutzsysteme fuer HERMES


    Contributors:

    Published in:

    SAE-Papers ; Apr ; 1-5


    Publication date :

    1988


    Size :

    5 Seiten, 11 Bilder


    Type of media :

    Conference paper


    Type of material :

    Print


    Language :

    English




    Passive Thermal Protection Systems for HERMES