The Space Shuttle Main Engines Nozzles consist of over one thousand tapered Inconel coolant tubes brazed to a stainless steel structural jacket. Liquid Hydrogen flows through the tubing, from the aft to forward end of the nozzle, under high pressure to maintain a thermal balance between the rocket exhaust and the nozzle wall. Three potential problems occur within the SSME nozzle coolant tubes as a result of manufacturing anomalies and the highly volatile service environment including poor or incomplete bonding of the tubes to the structural jacket, cold wall leaks and hot wall leaks. Of these conditions the identification of cold wall leaks has been the most problematic. The methods and results presented in this summary addresses the thermographic identification of cold wall 'interstitial' leaks between the structural jacket and coolant tubes of the Space Shuttle Main Engines Nozzles.


    Access

    Access via TIB

    Check availability in my library


    Export, share and cite



    Title :

    Thermographic Leak Detection of the Space Shuttle Main Engine Nozzle


    Contributors:

    Publication date :

    1999


    Size :

    pages


    Type of media :

    Report


    Type of material :

    No indication


    Language :

    English