The Space Shuttle Main Engines Nozzles consist of over one thousand tapered Inconel coolant tubes brazed to a stainless steel structural jacket. Liquid Hydrogen flows through the tubing, from the aft to forward end of the nozzle, under high pressure to maintain a thermal balance between the rocket exhaust and the nozzle wall. Three potential problems occur within the SSME nozzle coolant tubes as a result of manufacturing anomalies and the highly volatile service environment including poor or incomplete bonding of the tubes to the structural jacket, cold wall leaks and hot wall leaks. Of these conditions the identification of cold wall leaks has been the most problematic. The methods and results presented in this summary addresses the thermographic identification of cold wall 'interstitial' leaks between the structural jacket and coolant tubes of the Space Shuttle Main Engines Nozzles.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Thermographic Leak Detection of the Space Shuttle Main Engine Nozzle


    Beteiligte:
    J. L. Walker (Autor:in) / S. S. Russell (Autor:in)

    Erscheinungsdatum :

    1999


    Format / Umfang :

    pages


    Medientyp :

    Report


    Format :

    Keine Angabe


    Sprache :

    Englisch