New installation is designed to maintain, in spaces served, average internal conditions of 80 F (26.7 C) dry-bulb and 67 F (19.4 C) wet-bulb at 51% RH, with respective external figures of 92 F (33.3 C), 80 F (26.7 C) and 58%; it incorporates 64 cooling units, comprises twin-duct system for first-class and part of cabin class accommodation, single-duct system for tourist class and balance of cabin class accommodation, additional system for new teenagers' room, and 41 local cooling units for hot points in galleys, laundries and other service areas. (see also Heating and Vent Engr v 39 n 465 Apr 1966 p 583-6, 590)
Air conditioning -- New installation aboard Queen Elizabeth
Shipbldg Shipg Rec
Shipbuilding and Shipping Record ; 107 , n 6 ; p 525-526
1966
2 pages
Aufsatz (Zeitschrift)
Englisch
© Metadata Copyright Elsevier B. V. All rights reserved.