Serious guidance problem is introduction of amplitude-modulated (AM) or phase-modulated (PM) noise onto transmitted signal by rocket exhaust plume; results of set of measurements wherein X-band attenuation was measured simultaneously with AM/PM noise for seven different double-base propellant systems and single rubber-base system; results are reported for total attenuation and AM/PM noise, together with spectral distributions of noise, generally between 3.9 and 40 kc.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Rocket exhaust plume radar attenuation and amplitude/phase noise


    Weitere Titelangaben:

    J Spacecraft Rockets


    Beteiligte:
    Smoot, L.D. (Autor:in) / Seliga, Jr., T.J. (Autor:in)

    Erschienen in:

    Erscheinungsdatum :

    1967


    Format / Umfang :

    7 pages


    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Print


    Sprache :

    Englisch


    Schlagwörter :