This paper deals with the state variables (Temperatures) estimation for a counter-flow doublepipe heat exchanger using Multi-linear Models using a Kalman filter (FK) for the state variables approaching and using Bayes probability for the change of the model. The reliability of the proposed method was demonstrated via numerical simulation and laboratory experiments with a bench-scale pilot plant.
State Variables Estimation for a Counter-Flow Double-Pipe Heat Exchanger Using Multi-linear Model
01.09.2009
923043 byte
Aufsatz (Konferenz)
Elektronische Ressource
Englisch
Double-pipe heat exchanger including integrated connector
Europäisches Patentamt | 2022
|Double-row-pipe parallel flow heat exchanger and automobile air conditioning system
Europäisches Patentamt | 2023
|