This paper presents a Look-Up Table (LUT)-based decoupling method with Proportional Integrator (PI) control for Triple-Active-Bridge (TAB) converters within DC microgrids. The proposed approach, a validated TAB converter operating at 50 kHz, achieves a significant reduction in power decoupling, with 95.4% reduction for port 2 and 97.5% reduction for port 3 power variations. Simulation results from a TAB converter validate the effectiveness of the proposed approach for 1.7 kW TAB converter, showcasing the successful operation of constant current and voltage control without interference between ports.
Power Decoupling Control for Triple Active Bridge in DC Microgrids
31.07.2024
1307209 byte
Aufsatz (Konferenz)
Elektronische Ressource
Englisch
Decoupling Control for Active Magnetic Bearing
British Library Online Contents | 1999
|British Library Conference Proceedings | 2020
|