The operational features of the Constant Voltage Anemometer (CVA) are shown to be well adapted for measurements in supersonic flows. The time constant of hot-wire under constant voltage operation is verified to be much smaller than that under constant current operation. Good noise immunity feature of the constant voltage operation with large bandwidth of the CVA circuit were also noticed from the experiments. An extensive investigation has been conducted in a Mach 2.3 boundary layer. The software compensation approach described in an earlier study is again applied to the data in the present experiments. The approach of compensating the CVA for the hot-wire time constant partially with hardware during the experiment and later correcting the CVA output with the actual in-situ measured time constant has produced consistently good results with an increased bandwidth. The turbulence levels estimates deduced from CVA data collected at different wire overheats agree well with earlier published results. Comparisons with the Constant Current Anemometer (CCA) and the Constant Temperature Anemometer (CTA) were conducted in the same experimental conditions.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Performance studies of the constant voltage anemometer in a Mach 2.3 boundary layer


    Beteiligte:
    Comte-Bellot, G. (Autor:in) / Sarma, G.R. (Autor:in) / Faure, T.M. (Autor:in) / Dussauge, J.-P. (Autor:in) / Dupont, P. (Autor:in) / Debieve, J.-F. (Autor:in)


    Erscheinungsdatum :

    01.01.1999


    Format / Umfang :

    686969 byte




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch



    Performance Studies of the Constant Voltage Anemometer in a Mach 2.3 Boundary Layer

    Comte-Bellot, G. / Sarma, G. / Faure, T. et al. | British Library Conference Proceedings | 1999


    Constant-Temperature and Constant-Voltage Anemometer Use in a Mach 2.5 Flow.

    Julien Weiss / Ndaona Chokani / Geneviève Comte-Bellot | AIAA | 2005



    COMPARISON BETWEEN A HYBRID CONSTANT-CURRENT ANEMOMETER AND CONSTANT-VOLTAGE ANEMOMETER IN HYPERSONIC FLOW

    Chokani, N. / Shiplyuk, A. N. / Sidorenko, A. A. et al. | British Library Conference Proceedings | 2004


    Comparison Between a Hybrid Constant-Current Anemometer and Constant-Voltage Anemometer in Hypersonic Flow

    Chokani, Ndaona / Shiplyuk, Alexander / Sidorenko, Andrei et al. | AIAA | 2004