Low frequency modulation strategies are a good solution to increase the energy conversion efficiency in high power applications. The paper is devoted to presents an innovative way to low order harmonics mitigation for seven-level Cascaded H-Bridge Inverters. In particular, this approach is based on the mitigation of selected harmonics without solve non-linear equations for an extended range of the fundamental amplitude. In fact, in real-time operation to evaluate the control angles the polynomial equations have been identified. Through circuit simulation analysis in MatLab/PLECS environment, the effectiveness of the harmonic mitigation method has been tested and compared with theoretical results.
Innovative Computational Approach to Harmonic Mitigation for Seven-level Cascaded H-Bridge Inverters