For the machines powered by SiC inverters, the high voltage variation rate (dv/dt) leads to uneven voltage distribution in windings, and affects the insulation service life. To predict the influence of SiC inverter steep voltage waveform on the voltage distribution, a high frequency transmission line model is studied in this paper. The capacitance and impedance parameters at different frequencies, which are used in the studied model, are simulated with finite element method considering the laminated structure of silicon steel sheets. Further more, the frequency domain characteristics of the winding impedance are derived with vector fitting method. Based on the studied model, using the simulated and derived parameters, time domain simulation is carried out to predict the voltage distribution in each turn of the coil, and compared with the experimental results.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Voltage Distribution Analysis of High dv/dt Fed Machines Using High Frequency Winding Model


    Beteiligte:
    Zhang, Chenyue (Autor:in) / Wang, Yunchong (Autor:in) / Long, Tan (Autor:in) / Huang, Xiaoyan (Autor:in)


    Erscheinungsdatum :

    28.10.2022


    Format / Umfang :

    1117177 byte




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch



    High frequency model of transformer winding

    Shibuya, Yoshikazu | Online Contents | 2004



    Asymmetric Bar Winding for High-Speed Traction Electric Machines

    Islam, Md Sariful / Husain, Iqbal / Ahmed, Adeeb et al. | IEEE | 2020


    Automatic cell winding machines

    Ellis, Mark | Online Contents | 1995