This paper analyses the DC winding induced voltage in a partitioned-stator hybrid-excited switched-flux permanent magnet (PS-HESFPM) machine under open-circuit operation. The phenomenon and mechanism of the open-circuit DC winding induced voltage are described. Two techniques are proposed and comparatively analyzed by the finite element (FE) method to reduce the open-circuit DC winding induced voltage, i.e., rotor pole arc pairing and unevenly distributed rotor teeth, respectively. FE results show that the peak to peak value of the open-circuit DC winding induced voltage can be reduced by 89.89% and 88.73%, whilst the average on-load electromagnetic torque can be maintained at 97.64% and 97.02%, by using rotor pole arc paring and unevenly distributed rotor teeth, respectively.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Analysis of Open-Circuit DC Winding Induced Voltage in Partitioned-Stator Hybrid-Excited Switched-Flux Machine


    Beteiligte:
    Sun, X.Y. (Autor:in) / Zhu, Z.Q. (Autor:in)


    Erscheinungsdatum :

    01.05.2019


    Format / Umfang :

    1118791 byte




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch