This report discusses a variation of a previously described two channel system employing changeover contactors. The total generator capacity for such a system may be reduced from twice to four-thirds of the maximum aircraft load if, in the event of the failure of one channel, it is possible to discard one-third of the load without affecting the safety of the aircraft or the success of its mission. The inessential part of the load is connected to a third bus-bar which is automatically disconnected if either generator has an overload in excess of 10%. The basic merits of the original scheme, simplicity and very short interruption times when faults occur, are not affected. (Author)


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    A Light-Weight Aircraft Electric Power Supply System Using Changeover Contactors


    Beteiligte:
    R. F. Sims (Autor:in) / R. L. A. McKenzie (Autor:in)

    Erscheinungsdatum :

    1965


    Format / Umfang :

    16 pages


    Medientyp :

    Report


    Format :

    Keine Angabe


    Sprache :

    Englisch




    Sequential closing of electric vehicle power supply equipment contactors

    MESCISAN H ¨ / L ¨ ¨ NE / MUKBIEL MARTIN et al. | Europäisches Patentamt | 2025

    Freier Zugriff


    POWER SUPPLY CHANGEOVER NOTIFICATION DEVICE FOR TRAFFIC SIGNAL SYSTEM

    HIRATA YOSHIKI / MANABE FUMIO / TAKASHIMA SHUNICHIRO et al. | Europäisches Patentamt | 2021

    Freier Zugriff

    SEQUENTIAL CLOSING OF ELECTRIC VEHICLE SUPPLY EQUIPMENT CONTACTORS

    MHIESAN HAIDER / MOKBEL MOHAMAD / HARRIS TIMOTHY et al. | Europäisches Patentamt | 2025

    Freier Zugriff

    POWER CHANGEOVER DEVICE

    HAIJIMA TAKAAKI | Europäisches Patentamt | 2015

    Freier Zugriff