The burnthrough resistance of aircraft fuselages to external fuel fire was investigated in this test series. Three tests were conducted in a wheels-up mode and three in the wheels-down configuration. A comprehensive data base was developed documenting fire entry paths, burnthrough time, and cabin environmental conditions. The overall resistance of the two test intact aircraft fuselages to fire penetration was documented.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Fuselage Burnthrough from Large Exterior Fuel Fires


    Beteiligte:
    H. Webster (Autor:in)

    Erscheinungsdatum :

    1994


    Format / Umfang :

    150 pages


    Medientyp :

    Report


    Format :

    Keine Angabe


    Sprache :

    Englisch




    Full Scale Fuselage Burnthrough Tests

    Sarkos, G. | British Library Conference Proceedings | 1991


    Aircraft fuselage having burnthrough resistant components

    MUELLER RAINER / HUEBNER ROBERT / BUSCH HEINZ-PETER et al. | Europäisches Patentamt | 2018

    Freier Zugriff

    Burnthrough Resistance of Fuselage and Cabin Structures

    Povey, N. J. / Dodd, D. C. / Marker, T. R. et al. | British Library Conference Proceedings | 1997


    Full-Scale Air Transport Category Fuselage Burnthrough Tests

    H. Webster / G. Geyer / D. Do et al. | NTIS | 1990


    BURNTHROUGH PROTECTION SYSTEM

    FERNANDO JOSEPH A / GARVEY CHAD E / RIOUX ROBERT et al. | Europäisches Patentamt | 2017

    Freier Zugriff