During the week of 19 July 1976, a full-scale fire test series was performed at the U.S. Coast Guard Fire and Safety Test Detachment to examine the potential Fire hazards of intermodal shipping containers. The three-part test series was conducted on Little Sand Island in Mobile Bay, Alabama. The first sequence of tests were planned to evaluate whether a fire originating within a sealed intermodal container could burn through the container shell. The second task of the test series was to determine the effects of an exterior pool fire exposure on a single level of containers, and the final task was to evaluate the effects of an exterior pool fire exposure on a stack of containers. Standard 8 foot by 8 foot by 20 foot steel, aluminum and fiberglass-reinforced plywood shipping containers were tested. The interior fire tests utilized two 30-pound wood cribs constructed of white fir and 2 gallons of naptha as a fuel source. For the exterior fire tests, a 29 x 24 foot steel test pan containing JP-5 was constructed beneathe the container stack. Standard container stacking and lashing arrangements were used for all tests. (Author)


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Fire Performance of Intermodal Shipping Containers


    Beteiligte:
    R. Eberly (Autor:in)

    Erscheinungsdatum :

    1977


    Format / Umfang :

    62 pages


    Medientyp :

    Report


    Format :

    Keine Angabe


    Sprache :

    Englisch




    Intermodal shipping

    TIBKAT | 29.1994,7 - 31.1996,6; damit Ersch. eingest.


    MODULAR INTERMODAL SHIPPING CONTAINER

    EISOLD DAINE EDWARD | Europäisches Patentamt | 2024

    Freier Zugriff


    Handling Intermodal and Interline Containers

    Schultz, Gregory V. | SAE Technical Papers | 1972


    Shipping Containers

    CLIVE-SMITH MARTIN | Europäisches Patentamt | 2021

    Freier Zugriff