The GRI Pipeline Simulation Facility contains a 4700-foot-long loop of 24-inch-diameter pipe which can be used to simulate conditions in a natural gas pipeline. The flow loop is designed to support research, development, and demonstrations of in-line inspection technologies and equipment. A prototype magnetic flux leakage device was being propelled through the loop using compressed air as the pressurizing medium. Through a sequence of events, a fire initiated and the components of the pig train (magnetizer, instrumentation canister, and pusher pit) began to burn. The pig train travelled another 450-feet as the fire progressed forward to other components. At this point, the pig train stopped, and the pipeline became overheated and ruptured.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Investigation of the Failure in GRI's Pipeline Simulation Facility Flow Loop. Final Report, October 1995-May 1996


    Beteiligte:
    P. H. Vieth (Autor:in) / W. A. Maxey (Autor:in) / R. E. Mesloh (Autor:in) / J. F. Kiefner (Autor:in) / G. M. Williams (Autor:in)

    Erscheinungsdatum :

    1996


    Format / Umfang :

    138 pages


    Medientyp :

    Report


    Format :

    Keine Angabe


    Sprache :

    Englisch