Before the spacecraft returned to Earth in September, the Genesis mission had a preliminary assessment plan in place for the purpose of providing information on the condition and availability of collector materials to the science community as a basis for allocation requests. One important component of that plan was the evaluation of collector surfaces for molecular contamination. Sources of molecular contamination might be the on-orbit outgassing of spacecraft and science canister components, the condensation of thruster by-products during spacecraft maneuvers, or the condensation of volatile species associated with reentry. Although the non-nominal return of the Genesis spacecraft introduced particulate contamination to the collectors, such as dust and heatshield carbon-carbon, it is unlikely to have caused any molecular deposition. The contingency teams quick action in returning the damaged payload the UTTR cleanroom by 6 PM the evening of recovery help to ensure that exposure to weather conditions and the environment were kept to a minimum.
Analysis of Molecular Contamination on Genesis Collectors through Spectroscopic Ellipsometry
2005
6 pages
Report
Keine Angabe
Englisch
Genesis: Removing Contamination from Sample Collectors
British Library Conference Proceedings | 2005
|Spectroscopic Ellipsometry as a Sensitive Monitor of Materials Contamination
British Library Conference Proceedings | 1995
|Genesis Preliminary Examination: Ellipsometry Overview
NTRS | 2005
|Genesis Preliminary Examination - Ellipsometry Overview
NTIS | 2005
|