Assessment of the Apollo 13 mission indicated that some design changes to be incorporated into Apollo cryogenic oxygen storage tanks. These changes broadly fit into three categories. They were: (1) deletion of the fluid equilibration motors and redesign of heater assembly, (2) material changes for internal tank wiring and density sensor, and (3) the addition of a heater assembly temperature sensor. Development of a cryogenic oxygen tank incorporating these changes is presented.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Modified Apollo cryogenic oxygen tank design


    Beteiligte:
    Vanleuven, K. (Autor:in)


    Erscheinungsdatum :

    01.05.1971


    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Keine Angabe


    Sprache :

    Englisch


    Schlagwörter :



    APOLLO Oxygen Tank Stratification Analysis, Volume 2

    J. E. Barton / H. W. Patterson | NTIS | 1972


    Apollo oxygen tank stratification analysis, volume 2

    Barton, J. E. / Patterson, H. W. | NTRS | 1972


    Apollo oxygen tank stratification analysis, volume 1

    Barton, J. E. / Patterson, H. W. / Rule, D. D. | NTRS | 1971