Evacuation areas are defined for those transportation accidents where volatile chemical propellant tanks are exposed to fire in the wreckage and eventually explode with consequent risks from fragments in surrounding populated areas. An evacuation area with a minimum radius of 600 m is recommended to limit the statistical probability of fatality to one in 100 such accidents. The result of this study was made possible by the derivation of a distribution function of distances reached by fragments from bursting chemical car tanks. Data concerning fragments were obtained from reports of tank car pressure bursts between 1958 and 1971.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Evacuation areas for transportation accidents involving propellant tank pressure bursts


    Beteiligte:
    Siewert, R. D. (Autor:in)

    Kongress:

    JANNAF Propulsion Meeting ; 1972 ; New Orleans, LA


    Erscheinungsdatum :

    01.11.1972


    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Keine Angabe


    Sprache :

    Englisch






    RAILWAY TANK FOR LIQUID PROPELLANT TRANSPORTATION

    ROMASHENKO VIKTOR VIKTOROVICH / SHEKHOVTSOVA IRINA PETROVNA / POGREBNYAK VIKTOR ANDREEVICH et al. | Europäisches Patentamt | 2019

    Freier Zugriff

    Severities of Transportation Accidents Involving Large Packages

    A. W. Dennis / J. T. Foley / W. F. Hartman et al. | NTIS | 1978