Different tests on a flight type cell are discussed. The temperature was measured at the cell flange. The cell was charged to rollover at .75 C rate at 40 degrees C for the first temperature. At that point a voltage reading was taken. Charging was done for an arbitrary ten seconds at .75 C, 30 C, 20 C, 10 C and zero C to obtain momentarily stable voltages.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Some properties of NiH2 cells


    Beteiligte:
    Rogers, H. H. (Autor:in)


    Erscheinungsdatum :

    01.03.1982


    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Keine Angabe


    Sprache :

    Englisch




    5.5 Inches Diameter NiH2 Cells

    Castric, A. F. / Borthomieu, Y. | British Library Online Contents | 1998


    5.5 Inches Diameter NiH2 Cells

    Castric, A. F. / Borthomieu, Y. / European Space Agency | British Library Conference Proceedings | 1998


    NiH2 cell test update

    Mueller, V. C. | NTRS | 1982


    NiH2 battery model requirements

    Hafen, D. P. / Armantrout, J. D. | NTRS | 1996


    NiH2 LEO Cycle Life Study

    Hollandsworth, Roger P. / Armantrout, Jon D. / Rao, Gopalakrishna M. | NTRS | 2003