An investigation has been conducted to provide some insight into the effect of several geometric parameters on the internal performance of thrust reverser ports for nonaxisymmetric nozzles using a single port test apparatus. This test apparatus simulates thrust reversal (conceptually) which would occur in the convergent section of the forward flight nozzle or in the constant area duct just upstream. The port opening had an aspect ratio of 6.1 (throat width/throat height) and had constant passage area from the geometric throat to the exit. The geometric parameters investigated were port angle, port corner radius, port location, and flow blocker angle. The apparatus had a single port so that thrust (vector) angle could be obtained from force balance measurements. The tests were conducted in the Static Test Stand of the Langley 16-Foot Transonic Tunnel at nozzle pressure ratios from 1.5 to 8.0 using high pressure air for propulsion simulation. Port angles (measured forward from a horizontal reference line) investigated were 75, 90, 120 and 135 deg. Sharp and rounded port corners were investigated for each port angle. Discharge coefficient, thrust ratio, and passage static pressures were measured.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Port geometry effects on thrust reverser static performance


    Beteiligte:
    Re, R. J. (Autor:in) / Mason, M. L. (Autor:in)

    Erscheinungsdatum :

    01.07.1985


    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Keine Angabe


    Sprache :

    Englisch