The operational experience of a large turbine drive carbon dioxide compressor train in a urea plant with capacity of 1620 tons/day is considered. After the initial start-up in 1976, the vibration in the HP cylinder was comparatively serious. The radial vibration reached 4.2 to 4.5 mils and fluctuated around this value. It was attributed to the rotating stall based on the spectrum analysis. Additional return line from the 4th to 4th and higher temperature of the 4th inlet has cured the vibration. Problems are described which were encountered in the operation along with their solutions, and/or improvements.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    CO2 compressor vibration and cause analysis


    Beteiligte:
    Ying, Y. L. (Autor:in)


    Erscheinungsdatum :

    01.12.1985


    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Keine Angabe


    Sprache :

    Englisch


    Schlagwörter :


    Root Cause Investigation of the Centrifugal Compressor Pulsation/Vibration Problems

    Motriuk, R. W. / Harvey, D. P. | British Library Online Contents | 1997



    Low-Vibration Oscillating Compressor

    Studer, P. A. | NTRS | 1984



    VIBRATION ISOLATOR FOR OIL-FREE COMPRESSOR

    LEE JAE YOUNG / OH CHOONG GEUN / KYUNG HWAN MIN | Europäisches Patentamt | 2020