A simulator study to determine the effect on pilot performance of electronically represented altitude and airspeed information on the primary flight display using moving tape formats is presented. The study used a seemingly random, unpredictable guidance task and focused on three areas relating to the representation of information on moving tape formats: tape centering, trend information, and tape orientation. Results suggest that moving tape displays with actual values centered is better than tapes with reference values centered and that high-to-low airspeed tape orientation is better than low-to-high orientation. With trend information absent, subjects devoted 50 percent more attention to the secondary task relative to display configurations with trend presented.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Subjective, physiological, and performance measures of eight primary flight displays


    Beteiligte:

    Kongress:

    International Symposium on Aviation Psychology ; 1987 ; Columbus, OH, United States


    Erscheinungsdatum :

    01.01.1987


    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Keine Angabe


    Sprache :

    Englisch


    Schlagwörter :



    Workload indices: physiological measures versus subjective ratings

    Veltman, H. / Gaillard, A. / Van Breda, L. et al. | British Library Conference Proceedings | 1997


    Mental Workload: Lessons Learned from Subjective and Physiological Measures

    Veltman | British Library Conference Proceedings | 2003


    FMS flight plans in synthetic vision primary flight displays

    He, Gang / Feyereisen, Thea / Wyatt, Sandy | SPIE | 2009


    Synthetic vision primary flight displays for helicopters

    He, Gang / Feyereisen, Thea / Wilson, Blake | SPIE | 2008