Proposed sorption refrigeration system of increased power efficiency combines MnxNy sorption refrigeration stage with systems described in "Regenerative Sorption Refrigerator" (NPO-17630). Measured pressure-vs-composition isotherms for reversible chemisorption of N2 in MnxNy suggest feasibility to incorporate MnxNy chemisorption stage in Joule-Thomson cryogenic system. Discovery represents first known reversible nitrogen chemisorption compression system. Has potential in nitrogen-isotope separation, nitrogen purification, or contamination-free nitrogen compression.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Manganese Nitride Sorption Joule-Thomson Refrigerator


    Beteiligte:

    Erschienen in:

    Erscheinungsdatum :

    01.07.1992



    Medientyp :

    Sonstige


    Format :

    Keine Angabe


    Sprache :

    Englisch


    Schlagwörter :


    Mixed-Gas Sorption Joule-Thomson Refrigerator

    Jones, Jack A. / Petrick, S. Walter / Bard, Steven | NTRS | 1991


    The Performance of Joule Thomson Refrigerator

    Hong, Y. / Park, S. / Kim, H. et al. | British Library Conference Proceedings | 2005


    The Performance of Joule Thomson Refrigerator

    Hong, Yong-Ju / Park, Seong-Je / Kim, Hyo-Bong et al. | Springer Verlag | 2005


    Joule-Thomson data curves

    Beimgraben, H. W. | NTRS | 1976


    Spring-Loaded Joule-Thomson Valve

    Jones, J. A. / Britcliffe, M. J. | NTRS | 1986