Report compares single-cycle with multiple-cycle mechanical-stress tests of parts under mechanical stresses. Objective of proof testing: to screen out gross manufacturing or material deficiencies and provide additional assurance of quality. Report concludes that changes in distribution of crack sizes during multicycle proof testing depend on initial distribution, number of cycles, relationship between resistance of material and elastic/plastic fracture-mechanics parameter, relationship between load control and displacement control, and magnitude of applied load or displacement. Whether single-cycle or multicycle testing used depends on shape, material, and technique of fabrication of components tested.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Single-Cycle Versus Multicycle Proof Testing


    Beteiligte:
    Hudak, S. J., Jr. (Autor:in) / Mcclung, R. C. (Autor:in) / Bartlett, M. L. (Autor:in) / Fitzgerald, J. H. (Autor:in) / Russell, D. A. (Autor:in)

    Erschienen in:

    Erscheinungsdatum :

    01.12.1992



    Medientyp :

    Sonstige


    Format :

    Keine Angabe


    Sprache :

    Englisch


    Schlagwörter :


    A comparison of single-cycle versus multi-cycle proof testing strategies

    Hudak, Stephen J., Jr. / Russell, Dale A. | NTRS | 1988



    Poled lithium niobate crystals enable multicycle THz pulse generation

    Lee, Y.-S. / Norris, T. B. | British Library Online Contents | 2005


    Performance Measurements of Multicycle Pulse-Detonation-Engine Exhaust Nozzles

    Daniel Allgood / Ephraim Gutmark / John Hoke et al. | AIAA | 2006


    Thrust Measurement of a Multicycle Partially Filled Pulse Detonation Rocket Engine

    Kasahara, Jiro / Hirano, Masao / Matsuo, Akiko et al. | AIAA | 2009