Several recently manufactured 50 and 60 ampere hour aerospace NiCd battery cell lots, produced by Gates Aerospace Batteries, are prone to premature on orbit performance degradation. The failure mechanism is cadmium migration, and the consequent development of soft shorts. A Martin Marietta Astronautics satellite program instituted an orbital management strategy for a set of these batteries that reduced the rate of degradation and brought the system to stable operation. This strategy involves: (1) minimizing the accumulated battery overcharge; (2) regular discharge exercises; and (3) periodic battery reconditioning. Because of changes in the NiCd cell manufacturing process, the actual performance of subsequent lots of NiCd cells is open to question. Future NiCd based power system designs should therefore allow for fine control of charge parameters, and an on orbit battery reconditioning capability. To minimize risk, it is much better to perform a full life test to qualify the cells before launch, rather than in parallel with orbital operations. If there are any changes in the manufacturing process of cells, it is extremely important to maintain very strong cognizance of secondary subcontractors, recognizing that the cell and battery manufacturing discipline is easily atrophied.
Orbital management and design considerations for NiCd satellite power systems
01.02.1994
Aufsatz (Konferenz)
Keine Angabe
Englisch
Orbital Management Considerations for NICD Satellite Power Systems
British Library Conference Proceedings | 1994
|Orbital Management and Design Considerations for Ni-Cd Satellite Power Systems
British Library Conference Proceedings | 1994
|NTRS | 1982
|Fur NiCd-Akkus: Rekonditionierungsschaltung
British Library Online Contents | 2007