This viewgraph presentation reviews the GSFC Cleanroom Facility i.e., Spacecraft Systems Development and Integration Facility (SSDIF) with particular interest in its use during the development of the Wide Field Camera 3 (WFC3). The SSDIF is described and a diagram of the SSDIF is shown. A Constraint Table was created for consistency within Contamination Control Team. This table is shown. Another table that shows the activities that were allowed during the integration under given WFC3 condition and activity location is presented. Three decision trees are shown for different phases of the work: (1) Hardware Relocation, Hardware Work, and Contamination Control Operations.
Practical Cleanroom Operations Constraints
01.01.2007
Aufsatz (Konferenz)
Keine Angabe
Englisch
CLEANROOM HOIST UNIT THAT BORROWS FROM SPECIALIZED HOISTING ACCESSORY FOR CLEANROOM EQUIPMENT
Europäisches Patentamt | 2024
|British Library Conference Proceedings | 2000
|JPL cleanroom practices and protocols
NTRS | 2017
|Resuspension Experiments of Cleanroom Particles
AIAA | 2025
|