An argued suggestion about the proper value of the heat-transfer coefficient to he assumed for describing the temperature transient in a pressurant tank under microgravity is presented. The heat-transfer coefficient to be used in a lumped mass approach to the problem is furnished via a proper Nusselt number. Transient analyses based on a continuous mass distribution or on a lumped mass approach, are compared.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Heat Transfer Analysis in Pressurizer Tank Under Microgravity


    Weitere Titelangaben:

    Sae Technical Papers


    Beteiligte:

    Kongress:

    Intersociety Conference on Environmental Systems ; 1986



    Erscheinungsdatum :

    14.07.1986




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch







    Two-Phase Flow Heat Transfer Under Microgravity Condition

    Parang, Masood / Tipton, J. / Garth, J. | AIAA | 2003


    TWO-PHASE FLOW HEAT TRANSFER UNDER MICROGRAVITY CONDITION

    Parang, M. / Tipton, J. B. / Garth, J. D. et al. | British Library Conference Proceedings | 2003