A large telescope aperture, stringent thermal stability and temperature range requirements, and a passively-cooled 150°K module presented major challenges in thermal design and hardware fabrication of this Small Explorer satellite. This paper reviews briefly the thermal design of the SWAS science instrument, and examines the first three months of on-orbit thermal history. Measured temperatures for both the science payload and the spacecraft module and solar arrays are compared with those predicted by the correlated analytical model. Similarities and differences are interpreted in terms of the major uncertainties remaining after thermal-balance testing, especially those of MLI performance and telescope aperture properties. Review of the thermal model adequacy and thermal design verification are included to suggest improvements in the thermal design process for future missions.
The Submillimeter-Wave Astronomy Satellite: On-Orbit Thermal Performance and Design Retrospective
Sae Technical Papers
International Conference On Environmental Systems ; 1999
12.07.1999
Aufsatz (Konferenz)
Englisch
The Submillimeter-Wave Astronomy Satellite: On-Orbit Thermal Performance and Design Retrospective
British Library Conference Proceedings | 1999
|The Submillimeter Wave Astronomy Satellite
Tema Archiv | 1991
|The Submillimeter-Wave Astronomy Satellite: Instrument Thermal Design and Verification
SAE Technical Papers | 1996
|Submillimeter Wave Astronomy Satellite (SWAS) Launch and Early Orbit Support Experiences
British Library Conference Proceedings | 1999
|