The shortened liquid cooling/warming garment (SLCWG) developed by the University of Minnesota group was compared with the standard NASA liquid cooling/ventilating garment (LCVG) garment during physical exertion in comfort (24°C) and hot (35°C) chamber environments. In both environmental conditions, the SLCWG was just as effective as the LCVG in maintaining rectal temperature (Tre) in a thermal comfort range; sweat production on the face was less; and subjective perception of overall and local body comfort was higher. The findings indicate that the SLCWG produces the same or greater comfort level as that achieved with the LCVG's total coverage of the body surface.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Comparison of Shortened and Standard Liquid Cooling Garments to Provide Physiological and Subjective Comfort During EVA


    Weitere Titelangaben:

    Sae Technical Papers


    Beteiligte:
    Coca, Aitor (Autor:in) / Graziosi, David (Autor:in) / Leon, Gloria R. (Autor:in) / Ferl, Jinny (Autor:in) / Koscheyev, Victor S. (Autor:in)

    Kongress:

    International Conference On Environmental Systems ; 2004



    Erscheinungsdatum :

    19.07.2004




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch




    Comparison of Shortened and Standard Liquid Cooling Garments to Provide Physiological and Subjective Comfori During EVA

    Koscheyev, V. S. / Leon, G. R. / Ferl, J. et al. | British Library Conference Proceedings | 2004


    Subjective Perception of Thermal and Physical Comfort in Three Liquid Cooling Garments

    Fink, Birgit / Leon, Gloria R. / Warpeha, Joe et al. | SAE | 2009