The peak current and vibration peak acceleration are two important parameters in the electroimpulse deicing system. Available data on two parameters are sparse. An experimental setup to measure the peak current and vibration peak acceleration in the electroimpulse deicing system is presented. The measurement is performed in the icing wind tunnel. Rogowski coil’s principle on pulsed current measurement is applied in the electroimpulse deicing discharge current circuit. It is found that calculated results agree with the measured trend. A piezoelectric vibration acceleration sensor is adopted to measure the vibration peak acceleration. Test results show that when the peak current varies linearly, the vibration peak acceleration increases with the increase of discharge voltages and its variation is approximately linear. The experimental results in the electroimpulse deicing system demonstrate that the proposed measuring method is accurate and reliable.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    On measuring key parameters of an electro-impulse deicing system


    Beteiligte:
    Du, Qian (Autor:in) / Zhu, Chunling (Autor:in)


    Erscheinungsdatum :

    01.05.2019


    Format / Umfang :

    8 pages




    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch