The results of preliminary tests on an active helicopter rotor blade are presented. The blade, a Mach-scaled model of a CH-47D helicopter blade, has a discrete piezoelectric actuator embedded within the spar that controls a trailing edge flap via a pushrod. Ultimately, the blade will be tested on a helicopter rotor hover stand at MIT. In this paper, we describe the tests performed prior to hover testing. First, the actuator was tested on the bench to determine its control authority and frequency response. Second, the actuator was tested on a shake table to simulate the out-of-plane accelerations that would be encountered in a full-scale helicopter in forward flight. Third, the actuator was embedded in the model blade, and its response to low-frequency sinusoidal actuation was obtained and compared to the bench test results. Finally, the frequency response of the actuator in the blade was determined using swept sine excitation. All test results indicate that the actuator should produce the desired level of control authority in the model-scale rotor.
Preliminary testing of a Mach-scaled active rotor blade with a trailing-edge servo flap
Smart Structures and Materials 1999: Smart Structures and Integrated Systems ; 1999 ; Newport Beach,CA,USA
Proc. SPIE ; 3668
09.06.1999
Aufsatz (Konferenz)
Elektronische Ressource
Englisch
Analysis and testing of mach-scaled rotor with trailing-edge flaps
Tema Archiv | 2000
|ACTIVE ROTOR CONTROL (ARC) OF A MACH-SCALE TRAILING EDGE FLAP ROTOR