A resonant body has been tested and analyzed to determine its SGEMP response. Both electrical and photon excitation were used and their results compare favorable with predictions. A modal analysis of the experimental data using Prony's algorithm yielded the dominant frequencies, damping and excitation amplitudes. Within the accuracy of the measurements, the presence of the photon-induced electron cloud had no effect on the period or damping times of the RESMOD modes. The proximity of an electrical pulser and its 200-Ohm terminating resistor markedly decreased the damping time during electrical excitation.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Electrical and photon tests of a resonant satellite shape


    Weitere Titelangaben:

    Testuntersuchungen mit elektrischer und Photonenanregung eines Satellitenkoerpers


    Beteiligte:
    Price, M.L. (Autor:in) / Lint, V.A.van (Autor:in) / Fromme, D.A. (Autor:in)

    Erschienen in:

    Erscheinungsdatum :

    1978


    Format / Umfang :

    7 Seiten, 7 Bilder, 4 Tabellen, 5 Quellen



    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Print


    Sprache :

    Englisch




    Analysis and tests of a satellite model in a photon environment

    Kaiser, R. / Swift, D. | Tema Archiv | 1977


    Resonant Control of Satellite Orbits

    Nie, Tao / Gurfil, Pini | AIAA | 2021


    A single-photon resonant-cavity LED

    Bennett, A.J. / Unitt, D.C. / See, P. et al. | IEEE | 2005


    Satellite takes shape

    Engineering Index Backfile | 1948


    Satellite takes shape

    Engineering Index Backfile | 1948