Analyses and computer simulations during the front-end engineering design of a high-pressure natural gas pipeline predicted that, without suitable mitigation, steady-state AC potentials (referenced to local earth) on the pipeline would easily exceed 100 V. Similarly, the analysis predicted AC coating stress and touch potentials approaching 12,000 V predicted during a power-line-to-ground fault. Coordination of AC mitigation and cathodic protection ensures adequate electric safety and effective corrosion control. The paper discusses aspects of coordinated design, construction, and commissioning of an AC mitigation and cathodic-protection system consisting of one steel-cored zinc ribbon adjacent to the pipeline.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Reducing AC potentials requires coordinated mitigation, CP


    Weitere Titelangaben:

    Verringerung von Wechselstrompotenzialen erfordert koordinierte Einflussminderung und kathodischen Korrosionsschutz


    Beteiligte:
    Lindemuth, Dale (Autor:in) / Creel, Jerry (Autor:in)

    Erschienen in:

    Oil and Gas Journal ; 108 , 23 ; 51-56


    Erscheinungsdatum :

    2010


    Format / Umfang :

    6 Seiten, 7 Bilder, 4 Quellen



    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Print


    Sprache :