The incorporation of a multiphase flow meter (MPFM) in the subsea production manifold on the UK South Scott Field had two main benefits. It reduced the complexity of the infrastructure required to develop the field by eliminating the need for a dedicated test pipeline and riser system, and significantly reduced the project capital expenditure. The application provided the opportunity to deliver benefits to the production and reservoir engineering community by allowing real-time monitoring of well tests. Despite the testing undertaken during the development program, the South Scott MPFM experienced component failure which resulted in the recovery of the meter and a failure investigation.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Development and use of a subsea multiphase flow meter on the UK South Scott field


    Beteiligte:
    Slater, S.G. (Autor:in) / Paterson, A.McK. (Autor:in) / Marshall, M.F. (Autor:in)


    Erscheinungsdatum :

    1997


    Format / Umfang :

    Seiten, 8 Quellen


    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch




    MMS 1200: A PETROBRAS and FLUENTA cooperation on a subsea multiphase flow meter application

    Caetano, E.F. / Pinheiro, J.A.S.F. / Moreira, C.C. et al. | Tema Archiv | 1997


    Subsea multiphase metering

    Vagen, N.J. / Hanssen, B.V. | Tema Archiv | 1999



    The multiphase key to subsea production

    Mayhew, G. | Tema Archiv | 1990


    SBMS-500: Cooperation on a subsea multiphase flow pumping system

    Caetano, E.F. / Silva, R.M. / Lopes, M.A.A. et al. | Tema Archiv | 1997